Aquametrix SHARK-120/240 Controllers Datasheet User Manual

Browse online or download User Manual for Accessories for water Aquametrix SHARK-120/240 Controllers Datasheet. Aquametrix SHARK-120/240 Controllers Datasheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 3
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SUMMARY
The SHARK series is designed to be the most
exible, easy to use, and easy to see multi-pa-
rameter controller/analyzer on the market.
FOUR MEASURING PARAMETERS
Select the parameter you wish to measure from
the easy-to-use LCD menu on the inside front
cover. Choose Conductivity, pH, ORP or Flow.
NO EXTRA CARDS / OPTIONS RE-
QUIRED
Each SHARK comes complete. There are no
extra costs associated with buying boards for
different applications, or buying components to
achieve NEMA 4X.
UNIVERSAL MOUNTING
Universal mounting kit is included for surface,
panel and pipe-mount applications. The 1/4 DIN
enclosure makes panel-mount cutouts and engi-
neering simple.
SNAP-ON TERMINAL CONNECTORS
Wiring is easy with removable / snap-on terminal
connectors.
DISPLAYS & MENUS
There are two displays on SHARK. A bright
LED numeric display with bar graph on the out-
side front panel,and a 2-line, 16-character LCD
display on the inside. The LED readout on the
outside panel can be seen several yards away.
The distinctive, color-coded bar graph will imme-
diately indicate if you are within the process pa-
rameters that you set (green), if the control relays
are on (yellow) and if you are in alarm condition
(red). This makes diagnosing pump and alarm
malfunctions easy. All conguration and control
functions are performed on the LCD menu on the
inside front panel.
CALIBRATION
Calibration is performed easily from the front
panel. Temperature (where applicable) is also
checked from the front. Since this routine main-
tenance does not require opening the front panel
to access the main menu on the inside congura-
tion settings cannot be adjusted by mistake. Pro-
cess and temperature (where applicable) calibra-
tion can also be performed from the LCD menu,
where calibration data (slope, temperature and
efciency) are displayed. pH can be calibrated
using Manual or Auto Calibration methods. Cali-
bration data can be recalled, indicating calibra-
tion mode, accepted buffer values, actual sensor
input signals, calibration temperature and more.
ANALOG OUTPUTS
The SHARK provides two isolated, independent
and scalable 4-20 mA outputs.
RELAYS WITH CYCLE TIMERS
The instrument also provides control of external
devices using its two independent control relays.
A third relay is pre-set to act as an alarm relay,
but can be used as a process control relay. It has
both high and low on setpoints with adjustable
off setpoints. Factory set for bidirectional control,
both control relays can be set for either a rising or
falling process, with easily programmed on set-
points and off setpoints. Each control relay has a
built-in independent cycle timer, with eld-set on
and off times. This feature enables tighter con-
trol of batch processes by eliminating chemical
overshoot.
ENCLOSURE
SHARK is packaged in a rugged NEMA 4X poly-
carbonate enclosure making it ideally suited for
heavy-duty applications such as industrial waste
water neutralization, municipal water and waste
water, pulp and paper, and process control.
pH, ORP, Conductivity & Flow
parameters available
Easy to read 4 digit LED dis-
play
Unique, bright & color-coded
bar graph display
Quick and easy to calibrate
Relay cycle on/off timers
Two control relays
Two 4-20 mA outputs with
range expandibility
High/Low alarm relay
1/4 DIN•NEMA 4X enclosure
Universal mounting hardware
provided for surface, panel and
pipe mounting
Compatible with AquaMetrix
models P/R60 differential pH/
ORP sensors, 500 series combi-
nation style pH/OR sensors, MS/
AM series conductivity cells, and
IP80/IP100/SPX ow sensors
Aquametrix SHARK
Multi-Parameter Controller
by
Water Analytics
Aqua
Metrix
100 School Street
Andover, MA 01810
978-749-9949
Toll free - 855-747-7623
www.WaterAnalytics.net
Description
Features
Applications
by
Water Analytics
Aqua
Metrix
Process Control
Industrial and Municipal Water
treatment
Industrial and Municipal Waste
treatment and Neutralization
Fume Scrubbers
Suitable for the Plating, Circuit
Board Manufacturing, Food and
Beverage, Chemical Processing,
Pulp & Paper, Mining, Nuclear
Energy and Pharmaceutical In-
dustries
Page view 0
1 2 3

Summary of Contents

Page 1 - Applications

SUMMARYThe SHARK series is designed to be the most exible, easy to use, and easy to see multi-pa-rameter controller/analyzer on the m

Page 2 - Technical Data

SHARK pH, ORP, Conductivity, Flow Controller / AnalyzerTechnical DatapH ORP Conductivity FlowDisplayFront Panel: 4 x 7 segment 1/2” LED display, 1 LED

Page 3 - Ordering Information

SHARK pH, ORP, Conductivity, Flow Controller / AnalyzerDimensions and Mounting Congurationswww.WaterAnalytics.net 978-749-9949 Toll free - 855-

Comments to this Manuals